← All controls

52 Alert-pipeline heartbeat

A synthetic event is fired on a fixed cadence through each alerting path, and a watcher pages when the expected alert fails to arrive inside its window. Detection pipelines fail silently — a rule edited, a recipient group emptied, a mail filter added — and a dead detector looks exactly like a quiet week. The heartbeat is what tells the two apart.

Caveats

Setup steps

  1. open ↗
    Admin console screen — Rules (Admin Console Home > Rules)

    https://admin.google.com/ac/ax · captured 2026-07-15

    Rules › Create rule › Activity
    Action
    Send to alert center + email notification to selected admin accounts (non-admin/external recipients must be reached via a Google Group)
    Severity
    Low

    Create and manage activity rules ↗

  2. Cadence
    daily, fixed UTC hour

    Installable Triggers ↗

  3. Missing heartbeat within window
    page on-call ('the detector is dead')

    Alert Center API overview ↗

  4. open ↗
    Admin console screen — Security > Alert center

    https://admin.google.com/ac/ac · captured 2026-07-15

    Security › Alert center

Ongoing maintenance

How to verify

  1. Trigger the synthetic event and confirm the alert lands in the monitored mailbox within the expected window — an alert pipeline is only verified by an alert.

v0.1.2Assure policy #33 · #12, #11 ↗